0x608f, 0x6090, Parameter setting & configuration factor group – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 67
EDS94TA11010xxxx EN 1.2 - 03/2010
L
67
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Factor group
0x608F - Position encoder resolution
0x6090 - Velocity encoder resolution
Index | Name:
0x608F | Position encoder resolution
Data type: UNSIGNED_32
Resolution of the position encoder
Subindex Name
Encoder increments
Motor revolution
Index | Name:
0x608F/1 | Encoder increments
Data type: UNSIGNED_32
Incremental encoder pulses
Setting range
(min. value | unit | max. value)
Lenze setting
65536
inc
65536 65536 inc
;
Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x608F/2 | Motor revolution
Data type: UNSIGNED_32
Number of motor revolutions
Setting range
(min. value | unit | max. value)
Lenze setting
1
rev
1 1 rev
;
Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6090 | Velocity encoder resolution
Data type: UNSIGNED_32
Resolution of the speed encoder
Subindex Name
Encoder increments per second
Motor revolutions per second
Index | Name:
0x6090/1 | Encoder increments per second
Data type: UNSIGNED_32
Incremental encoder pulses per second
Setting range
(min. value | unit | max. value)
Lenze setting
65536
inc/s
65536 65536 inc/s
;
Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6090/2 | Motor revolutions per second
Data type: UNSIGNED_32
Number of motor revolutions per second
Setting range
(min. value | unit | max. value)
Lenze setting
1
rev/s
1 1 rev/s
;