beautypg.com

Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 109

background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

109

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Homing mode

CiA02 homing method 25

Processes:

Case 1:

Axis does not activate reference switch on the way to the limit switch:

1. Movement in positive direction with profile data set 1.
2. Reversing to positive travel range limit switch.
3. The following positive edge of reference switch sets reference (

0x607C

).

4. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

Case 2:

Axis activates reference switch first on the way to the limit switch:

1. Movement in positive direction with profile data set 1.
2. The following positive edge of reference switch sets reference (

0x607C

).

3. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

Case 3:

Axis already stands on reference switch:

1. Movement in positive direction with profile data set 2.
2. Reversing with negative edge of reference switch.
3. The following positive edge of reference switch sets reference (

0x607C

).

4. Absolute positioning to target position (C02643) with profile data set 2 (if

0x60FB/

7

= "0").

 Homing switch

 Positive travel range limit switch

1

3

2

0

1