beautypg.com

0x6092, Parameter setting & configuration factor group – Lenze E94AxHE Technology Application CiA402 Device profile User Manual

Page 69

background image

EDS94TA11010xxxx EN 1.2 - 03/2010

L

69

9400 Technology applications | CiA402 device profile

Parameter setting & configuration

Factor group

0x6092 - Feed constant

Index | Name:

0x6092 | Feed constant

Data type: UNSIGNED_32

Code:

C03565

Feed constant

• The feed constant corresponds to the motion of the machine at one revolution of the gearbox output shaft.

Subindex Name

0x6092/1

Feed

0x6092/2

Shaft revolutions

Index | Name:

0x6092/1 | Feed

Data type: UNSIGNED_32

Code: C02524

Feed

• Direct mapping of the Lenze code C02524 (feed constant).
Setting range

(min. value | unit | max. value)

Lenze setting

1

pos unit

2147483647 65536 pos unit

;

Read access ; Write access ; CINH … PLC-STOP … PDO_MAP_RX … PDO_MAP_TX

Index | Name:

0x6092/2 | Shaft revolutions

Data type: UNSIGNED_32

Code:

C03567

Number of output shaft revolutions
Setting range

(min. value | unit | max. value)

Lenze setting

1

rev

1 1 rev

;