C03594 | following error time out, C03595 | position window, C03596 | position window time – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 210: C03597 | following error actual value, C03598 | control effort, C03599 | position control parameter set, Code, C03594, C03595, C03596
9400 Technology applications | CiA402 device profile
Parameter reference
Parameter list | C03594
210
L
EDS94TA11010xxxx EN 1.2 - 03/2010
C03594
C03595
C03596
C03597
C03598
C03599
Parameter | Name:
C03594 | Following error time out
Data type: UNSIGNED_32
Index: 20981
d
= 51F5
h
CiA402 object
Setting range
(min. value | unit | max. value)
Lenze setting
0
0 0
;
Read access ; Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C03595 | Position window
Data type: UNSIGNED_32
Index: 20980
d
= 51F4
h
CiA402 object
Setting range
(min. value | unit | max. value)
Lenze setting
0
4294967295 1000
;
Read access ; Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C03596 | Position window time
Data type: UNSIGNED_32
Index: 20979
d
= 51F3
h
CiA402 object
Setting range
(min. value | unit | max. value)
Lenze setting
0
0 0
;
Read access ; Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C03597 | Following error actual value
Data type: INTEGER_32
Index: 20978
d
= 51F2
h
CiA402 object
Display range
(min. value | unit | max. value)
-2147483647
2147483647
;
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C03598 | Control effort
Data type: INTEGER_32
Index: 20977
d
= 51F1
h
CiA402 object
Display range
(min. value | unit | max. value)
-2147483647
2147483647
;
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C03599 | Position control parameter set
Data type: UNSIGNED_32
Index: 20976
d
= 51F0
h
CiA402 object
Display range
(min. value | unit | max. value)
7
7
;
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1