9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Position control function
120
L
EDS94TA11010xxxx EN 1.2 - 03/2010
3.10.2
Object description
Except for the
object (control effort), all objects correspond to the CiA402
specification.
Objects described in other chapters:
Objects described in this chapter:
0x6062 - Position demand value unit
0x6063 - Position actual value*
Index
Name
Data type
Object type
Status word
UNSIGNED_16
VAR
Grayed out = read access only
Index
Name
Data type
Object type
Position demand value unit
INTEGER_32
VAR
Position demand value unit
INTEGER_32
VAR
Position actual value unit
INTEGER_32
VAR
Following error window
UNSIGNED_32
VAR
Following error time out
UNSIGNED_32
VAR
Position window
UNSIGNED_32
VAR
Position window time
UNSIGNED_32
VAR
Following error actual value
INTEGER_32
VAR
Control effort
INTEGER_32
VAR
Position control parameter set
UNSIGNED_32
RECORD
Position demand value*
INTEGER_32
VAR
Grayed out = read access only
Index | Name:
0x6062 | Position demand value unit
Data type: INTEGER_32
Interpolated position setpoint for position control in the user-defined [unit]
Display area
(min. value | unit | max. value)
-2147483648
pos unit
2147483647
;
Read access Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6063 | Position actual value*
Data type: INTEGER_32
Current position in [increments]
Display area
(min. value | unit | max. value)
-2147483648
inc
2147483647
;
Read access Write access CINH PLC-STOP PDO_MAP_RX ; PDO_MAP_TX