21 parameterisable function blocks, 1 adaption_positioncontroller, 2 adaption_speedcontroller – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 182: Parameterisable function blocks, Adaption_positioncontroller, Adaption_speedcontroller
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Parameterisable function blocks
182
L
EDS94TA11010xxxx EN 1.2 - 03/2010
3.21
Parameterisable function blocks
This subchapter lists all relevant parameterisable function blocks of the technology
application in alphabetical order with the corresponding parameters.
3.21.1
Adaption_Positioncontroller
3.21.2
Adaption_Speedcontroller
is ans instance of
Function
L_TbCurve
Adaption of the position controller by characteristic or curve function y = f(x)
Parameter
Possible settings
Information
C04103
Characteristic mode
0 Entire range
1 Symmetrical to the Y axis
Lenze setting
2 Symmetrical to the zero point
C04104/1...9
-200.00
%
200.00 x value of the characteristic function
• Subcode 1 ... 9 corresponding to
the support point values X1 ... X9.
C04105/1...9
-200.00
%
200.00 y value of the characteristic function
• Subcode 1 ... 9 corresponding to
the support point values Y1 ... Y9.
is ans instance of
Function
L_TbCurve
Adaption of the speed controller by the characterstic or curve function y = f(x)
Parameter
Possible settings
Information
C04100
Characteristic mode
0 Entire range
1 Symmetrical to the Y axis
Lenze setting
2 Symmetrical to the zero point
C04101/1...9
-200.00
%
200.00 x value of the characteristic function
• Subcode 1 ... 9 corresponding to
the support point values X1 ... X9.
C04102/1...9
-200.00
%
200.00 y value of the characteristic function
• Subcode 1 ... 9 corresponding to
the support point values Y1 ... Y9.