2 actual value and status signals, Actual value and status signals – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 17

EDS94TA11010xxxx EN 1.2 - 03/2010
L
17
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Assignment of the I/O terminals
3.2.2
Actual value and status signals
The following tables contain the Lenze assignment of the analog and digital outputs for
the "CiA402 device profile" technology application.
Analog outputs
Digital outputs
State bus
Display elements
Terminal X3
Signal (Lenze setting)
Signal configuration
AO1
No signal assigned
C03110/1
AO2
No signal assigned
C03110/2
Terminal X4
Signal (Lenze setting)
Signal configuration
DO1
Brake control (via contactor)
C03100/1
DO2
No signal assigned
• The DO2 digital output can be set via the master control via bit 1
of the
object (physical outputs).
C03100/2
DO3
No signal assigned
• The DO3 digital output can be set via the master control via bit 2
of the
object (physical outputs).
C03100/3
DO4
No signal assigned
• The DO4 digital output can be set via the master control via bit 3
of the
object (physical outputs).
C03100/4
Terminal X2
Signal (Lenze setting)
SB
State bus
• The state bus can be set to the "Fault" status by the master control via bit 4 of the
object (physical outputs).
• The state bus status can be queried via bit 5 of the
object (digital inputs).
User LED
Signal (Lenze setting)
No signal assigned
• The user LED can be controlled by the master control via bit 5 of the
object
(physical outputs) (0: LED off, 1: LED on).
GA
AO1
AO2
GO
24O
DO1
DO2
DO3
DO4
GE
24E
SB