Log buffered, Table 51. event message severity levels – Allied Telesis AT-9000 Series User Manual
Page 517

AT-9000 Switch Command Line User’s Guide
489
LOG BUFFERED
Syntax
log buffered level
level
program
program
Parameters
level
Specifies the minimum severity level of the event
messages to be stored in the event log. The log
stores the messages of the specified level and all
higher levels. For instance, if you specify level 4, the
log stores the messages for levels 0 and 4. The
available severity levels are listed in Table 51. The
default level 6 causes the log to store messages
with the severity level 0, 4, or 6.
program
Specifies the event messages of a particular
management software module. The modules are
listed in Table 53 on page 494. To specify more
than one module, separate the modules with
commas.
Mode
Global Configuration mode
Description
Use this command to specify the types of event messages to be stored in
the event log. You can specify the messages by severity level,
management software module, or both. The available severity levels are
listed in Table 51.
The management software modules are listed in Table 53 on page 494.
Table 51. Event Message Severity Levels
Severity
Description
0
Emergency message
4
Warning message
6
Informational message
7
Debug message