beautypg.com

Allied Telesis AT-9000 Series User Manual

Page 254

background image

Chapter 11: Power Over Ethernet

226

This example displays the PoE information of port 1 through port 4:

awplus# show power inline interface port1.0.1-port1.0.4

Figure 58 shows an example of the information the command displays.
The columns are described in Table 23 on page 247.

Figure 58. SHOW POWER-INLINE INTERFACE Command

This example displays the detailed PoE information of port 10:

awplus# show power inline interface port1.0.10 detail

Figure 59 shows an example of the information the command displays.
The columns are described in Table 25 on page 252.

Figure 59. SHOW POWER-INLINE INTERFACE DETAIL Command

Interface

Admin

Pri

Oper

Power

Device

Class

Max(mW)

port1.0.1

Disabled

Low

Disabled

0

n/a

0

15400 [C]

port1.0.2

Enabled

High

Powered

3840

Desk Phone

1

5000 [U]

port1.0.3

Enabled

Crit

Powered

6720

AccessPoint

2

7000 [C]

port1.0.4

Disabled

Low

Disabled

0

n/a

0

15400 [C]

Interface port1.0.10

Powered device type: Desk Phone #1

PoE admin enabled

Low Priority

Detection status: Powered

Current power consumption: 00 mW

Powered device class: 1

Power allocated: 5000 mW (from configuration)

Detection of legacy device is disabled

Powered pairs: Data