AT-9000 Switch Command Line User’s Guide
249
SHOW POWER-INLINE COUNTERS INTERFACE
Syntax
show power-inline counters interface
port
Parameter
port
Specifies a port. You can specify and display more than one port at
a time. Omit this parameter to display all of the ports.
Mode
Privileged Exec mode
Description
Use this command to display the PoE event counters for the ports. An
example is shown in Figure 61.
Figure 61. SHOW POWER-INLINE COUNTERS INTERFACE Command
The fields are described in Table 24.
PoE Counters:
Interface MPSAbsent Overload Short Invalid Denied
port1.0.4
0
0
0
0
0
port1.0.5
0
0
0
0
0
port1.0.6
0
0
0
0
0
Table 24. SHOW POWER-INLINE COUNTERS INTERFACE Command
Field
Description
Interface
The port number.
Overload
The number of times the PD exceeded the power limit
set with “POWER-INLINE MAX” on page 241.
Short
The number of short circuits the port has experienced.
Invalid
The number of times the port detected an invalid
signature. An invalid signature indicates an open circuit,
a short circuit, or a legacy PD.