SHOW POWER-INLINE COUNTERS INTERFACE

Syntax

show power-inline counters interface

port

Parameter

port

Specifies a port. You can specify and display more than one port at
a time. Omit this parameter to display all of the ports.

Mode

Privileged Exec mode

Description

Use this command to display the PoE event counters for the ports. An
example is shown in Figure 61.

Figure 61. SHOW POWER-INLINE COUNTERS INTERFACE Command

The fields are described in Table 24.

PoE Counters:

Interface MPSAbsent Overload Short Invalid Denied

port1.0.4

0

0

0

0

0

port1.0.5

0

0

0

0

0

port1.0.6

0

0

0

0

0

Table 24. SHOW POWER-INLINE COUNTERS INTERFACE Command

Field

Description

Interface

The port number.

Overload

The number of times the PD exceeded the power limit
set with “POWER-INLINE MAX” on page 241.

Short

The number of short circuits the port has experienced.

Invalid

The number of times the port detected an invalid
signature. An invalid signature indicates an open circuit,
a short circuit, or a legacy PD.