Table 4–7 describes the fields available in the Area Configuration area of the
Configure Thresholds tab.

Table 4–7: Configure Threshold Tab > Area Configuration Fields

Boundary - Custom Boundary Data

Unit:

Displays a number of units for the chosen area. Depending on
the area of interest, this is figured in units of “downs, reconfigs,
changes, logins”, etc.

Time Base

Displays the basic unit of time in which events are recorded for
the selected area. The units available from the drop-down
menu are: none, second, minute, hour, or day.

High

Displays the number of high boundaries (the highest limit at
which an element will not trigger an event) for the selected
area.

Low

Displays the number of low boundaries (the lowest limit at
which an element will not trigger an event) for the selected
area.

Buffer Size

Displays the threshold boundary buffer size of the selected
area.

Select
Boundary Level

Select either a custom or default setting for the boundary levels
from the drop-down menu.

Alarm Setting

Custom Alarm
Setting Data

Select Alarm settings for Errorlog, SNMP, RAN, and Email to
be active on switch side.

Select Alarm
Level

Select either a custom or default setting for the alarm levels to
be active on the switch side from the drop-down menu.

Update Flash

Check box to update Flash Memory.

Apply

Select to apply Fabric Watch area threshold and alarm setting
configuration. Changes will be lost if the Apply button is not
chosen before another you move to another tab.

Reset

Select to return fields to previous settings.