Enabling an error-disabled port manually, Setting the recovery interval, 328 and – Brocade FastIron Ethernet Switch Platform and Layer 2 Switching Configuration Guide User Manual
Page 329
NOTE
When automatic recovery re-enables the port, the port is not in the error-disabled state, but it can
remain down for other reasons, such as the Tx/Rx of the fibre optic not being seated properly. Thus, the
port is not able to receive the signal from the other side. In this case, after the optic is inserted correctly,
you should manually disable the port and then enable it.
Enabling an error-disabled port manually
To enable an error-disabled port manually, you must first run the disable command and then the
enable command in interface configuration mode to disable the port and then enable the port
respectively.
Setting the recovery interval
The errdisable recovery interval command allows you to configure a timeout for ports in the error-
disabled state, after which the ports are re-enabled automatically. To set the error-disabled recovery
timeout interval, enter the following command:
Brocade(config)# errdisable recovery interval 20
Syntax: [no] errdisable recovery interval seconds
The seconds variable allows you to set the timeout value for the recovery mechanism when the port is
in an errdisabled state. Once this timeout value expires, the ports are automatically re-enabled. Valid
values are from 10 through 65535 seconds.
Displaying the error disable recovery state by interface
The port status of errdisabled displays in the output of the show interface and the show interface
brief commands. In this example, errdisable is enabled on interface ethernet 1 and errdisable is
enabled because of a BPDU guard violation.
device#show interfaces ethernet 1
GigabitEthernet1 is ERR-DISABLED (bpduguard),
line protocol is down
BPDU guard is Enabled, ROOT protect is Disabled
Port down for 2 hours 45 minutes 10 seconds
Hardware is GigabitEthernet, address is 0000.00a0.7100 (bia 0000.00a0.7100)
Configured speed auto, actual unknown, configured duplex fdx, actual unknown
Configured mdi mode AUTO, actual unknown
Member of L2 VLAN ID 2, port is untagged, port state is DISABLED
STP configured to ON, priority is level0, flow control enabled
mirror disabled, monitor disabled
Not member of any active trunks
Not member of any configured trunks
No port name
IPG MII 96 bits-time, IPG GMII 96 bits-time
IP MTU 1500 bytes
300 second input rate: 0 bits/sec, 0 packets/sec, 0.00% utilization
300 second output rate: 0 bits/sec, 0 packets/sec, 0.00% utilization
145 packets input, 23561 bytes, 0 no buffer
Received 124 broadcasts, 21 multicasts, 0 unicasts
1 input errors, 0 CRC, 0 frame, 0 ignored
0 runts, 0 giants
5067 packets output, 330420 bytes, 0 underruns
Transmitted 90 broadcasts, 4977 multicasts, 0 unicasts
0 output errors, 0 collisions
Enabling an error-disabled port manually
FastIron Ethernet Switch Platform and Layer 2 Switching Configuration Guide
329
53-1003086-04