device(config)#lag lag3 static id 123
Error: LAG id 123 is already used. The next available LAG id is 2
.
NOTE
If you upgrade from an earlier version to a version with the LAG ID configuration feature, the old
configuration file will be parsed correctly and each LAG configured will get a LAG ID automatically.
!
lag lag1 static id 124
ports ethernet 1/1/2 to 1/1/3
primary-port 1/1/3
deploy
!
: show lag command and the output.
device(config)# show lag
Total number of LAGs: 5
Total number of deployed LAGs: 3
Total number of trunks created:2 (253 available)
LACP System Priority / ID: 1 / 0024.3889.3b00
LACP Long timeout: 120, default: 120
LACP Short timeout: 3, default: 3
=== LAG "test" ID 35 (static Deployed) ===
LAG Configuration:
Ports: e 3/10
Port Count: 1
Primary Port: 3/10
Trunk Type: hash-based
Deployment: HW Trunk ID 1
Port Link State Dupl Speed Trunk Tag Pvid Pri MAC Name
3/10 Down None None None 35 No 1 0 0024.3889.3b09
=== LAG "test2" ID 1 (static Deployed) ===
LAG Configuration:
Ports: e 3/11
Port Count: 1
Primary Port: 3/11
Trunk Type: hash-based
Deployment: HW Trunk ID 2
Port Link State Dupl Speed Trunk Tag Pvid Pri MAC Name
3/11 Down None None None 1 No 1 0 0024.3889.3b0a
=== LAG "test3" (keep-alive Deployed) ===
LAG Configuration:
Ports: e 3/12
Port Count: 1
Primary Port: 3/12
Trunk Type: hash-based
LACP Key: 9860
Deployment:
Port Link State Dupl Speed Trunk Tag Pvid Pri MAC Name
3/12 Down None None None None No 1 0 0024.3889.3b0b
Port [Sys P] [Port P] [ Key ] [Act][Tio][Agg][Syn][Col][Dis][Def][Exp][Ope]
3/12 1 1 9860 Yes S Agg Syn No No Def No Dwn
Partner Info and PDU Statistics
Port Partner Partner LACP LACP
System MAC Key Rx Count Tx Count
3/12 0000.0000.0000 139 0 0
=== LAG "test4" (keep-alive Not Deployed) ===
LAG Configuration:
Ports: e 3/13
Port Count: 1
Primary Port: 3/13
Trunk Type: hash-based
LACP Key: 0
=== LAG "test5" ID 2 (static Not Deployed) ===
LAG Configuration:
Ports: e 3/14
Port Count: 1
Primary Port: none
Link Aggregation
FastIron Ethernet Switch Platform and Layer 2 Switching Configuration Guide
141
53-1003086-04