CLI display of UDLD information (Continued)

TABLE 24

Field

Description

Keepalive Retries

The number of times a port will attempt the health check before concluding that
the link is down.

Keepalive Interval

The number of seconds between health check packets.

Port

The port number.

Physical Link

The state of the physical link. This is the link between the Brocade port and the
directly connected device.

Logical Link

The state of the logical link. This is the state of the link between this Brocade port
and the Brocade port on the other end of the link.

State

The traffic state of the port.

Link-vlan

The ID of the tagged VLAN in the UDLD packet.

If a port is disabled by UDLD, the change also is indicated in the output of the show interfaces brief
command. An example is given below.

device#show interfaces brief

Port Link State Dupl Speed Trunk Tag Priori MAC Name

1/1 Up LK-DISABLE

None None None No level0 0000.00a9.bb00

1/2 Down None None None None No level0 0000.00a9.bb01

1/3 Down None None None None No level0 0000.00a9.bb02

1/4 Down None None None None No level0 0000.00a9.bb03

If the port was already down before you enabled UDLD for the port, the port state is listed as None.

Syntax: show interfaces brief

Displaying information for a single port

To display detailed UDLD information for a specific port, enter a command such as the following.

device#show link-keepalive ethernet 4/1

Current State : up Remote MAC Addr : 0000.00d2.5100

Local Port : 4/1 Remote Port : 2/1

Local System ID : e0927400 Remote System ID : e0d25100

Packets sent : 254 Packets received : 255

Transitions : 1 Link-vlan : 100

Port blocking : No BM disabled : No

Syntax: show link-keepalive [ ethernet [ slotnum/] portnum ]

CLI display of detailed UDLD information

TABLE 25

Field

Description

Current State

The state of the logical link. This is the link between this Brocade port and the Brocade port on
the other end of the link.

Remote MAC Addr The MAC address of the port or device at the remote end of the logical link.

Displaying information for a single port

FastIron Ethernet Switch Platform and Layer 2 Switching Configuration Guide

125