Displaying information about ethernet interfaces – Brocade FastIron Ethernet Switch Platform and Layer 2 Switching Configuration Guide User Manual
Page 192
Rbridge ID of the peer 100
Session state of the peer OPERATIONAL
Next message ID to be send 287
Keep Alive interval in seconds 30
Hold Time Out in seconds 90
Fast Failover is enable for the session
UP Time 0 days: 2 hr:22 min:58 sec
Number of tcp packet allocations failed 0
Message Init Keepalive Notify Application Badmessages
Send 3 2421 2 53 0
Receive 3 2415 0 37 0
TCP connection is up
TCP connection is initiated by 10.1.1.2
TCP connection tcbHandle not pending
TCP connection packets not received
**************TCP Connection Details*********************
TCP Connection state: ESTABLISHED Maximum segment size: 1436
Local host: 10.1.1.2, Local Port: 12203
Remote host: 10.1.1.1, Remote Port: 4175
ISentSeq: 1867652277 SendNext: 1867660731 TotUnAck: 0
TotSent: 8454 ReTrans: 9 UnAckSeq: 1867660731
IRcvSeq: 3439073167 RcvNext: 3439078415 SendWnd: 16384
TotalRcv: 5248 DupliRcv: 16 RcvWnd: 16384
SendQue: 0 RcvQue: 0 CngstWnd: 1452
Syntax: show cluster [ cluster_name/cluster-id ] ccp peer [ details ]
Displaying information about Ethernet interfaces
Use the show interface ethernet command to display information about Ethernet interfaces. The
MCT-related information is shown in bold in the following example.
device# show interface ethernet 7/1
...
GigabitEthernet7/1 is disabled, line protocol is down
Hardware is GigabitEthernet, address is 0024.3822.8260 (bia 0024.3822.8260)
Configured speed auto, actual unknown, configured duplex fdx, actual unknown
Configured mdi mode AUTO, actual unknown
Member of L2 VLAN ID 1, port is untagged, port state is DISABLED
BPDU guard is Disabled, ROOT protect is Disabled
Link Error Dampening is Disabled
STP configured to ON, priority is level0
Flow Control is config enabled, oper disabled, negotiation disabled
Mirror disabled, Monitor disabled
Not member of any active trunks
Not member of any configured trunks
No port name
IPG MII 96 bits-time, IPG GMII 96 bits-time
MTU 1500 bytes, encapsulation Ethernet
ICL port for icl1 in cluster id 1
300 second input rate: 0 bits/sec, 0 packets/sec, 0.00% utilization
300 second output rate: 0 bits/sec, 0 packets/sec, 0.00% utilization
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts, 0 multicasts, 0 unicasts
0 input errors, 0 CRC, 0 frame, 0 ignored
0 runts, 0 giants
0 packets output, 0 bytes, 0 underruns
Transmitted 0 broadcasts, 0 multicasts, 0 unicasts
0 output errors, 0 collisions
Relay Agent Information option: Disabled
show interface ethernet 7/3
GigabitEthernet7/3 is disabled, line protocol is down
Hardware is GigabitEthernet, address is 0024.3822.8262 (bia 0024.3822.8262)
Configured speed auto, actual unknown, configured duplex fdx, actual unknown
Configured mdi mode AUTO, actual unknown
Member of L2 VLAN ID 1, port is untagged, port state is DISABLED
BPDU guard is Disabled, ROOT protect is Disabled
Link Error Dampening is Disabled
STP configured to ON, priority is level0
Flow Control is config enabled, oper disabled, negotiation disabled
Mirror disabled, Monitor disabled
Not member of any active trunks
Not member of any configured trunks
No port name
Displaying information about Ethernet interfaces
192
FastIron Ethernet Switch Platform and Layer 2 Switching Configuration Guide
53-1003086-04