3 ground, Table23 grounds, Ground -6 – Motorola DSP56012 User Manual

Page 46: Table 2-3, Grounds -6

background image

2-6

DSP56012 User’s Manual

MOTOROLA

Signal Descriptions

Ground

2.3

GROUND

Table 2-3

Grounds

Ground Name

Description

GND

P

PLL Ground

—GND

P

is ground dedicated for PLL use. The connection should be

provided with an extremely low-impedance path to ground. V

CCP

should be

bypassed to GND

P

by a 0.1

µ

F capacitor located as close as possible to the chip

package.

GND

Q

Internal Logic Ground

—GND

Q

is an isolated ground for the internal processing

logic. This connection must be tied externally to all other chip ground
connections. The user must provide adequate external decoupling capacitors.

GND

A

A Ground

—GND

A

is an isolated ground for sections of the internal logic. This

connection must be tied externally to all other chip ground connections. The user
must provide adequate external decoupling capacitors.

GND

D

D Ground

—GND

D

is an isolated ground for sections of the internal logic. This

connection must be tied externally to all other chip ground connections. The user
must provide adequate external decoupling capacitors.

GND

H

Host Ground

—GND

H

is an isolated ground for the HI I/O drivers. This

connection must be tied externally to all other chip ground connections. The user
must provide adequate external decoupling capacitors.

GND

S

Serial Host Ground

—GND

S

is an isolated ground for the SHI I/O drivers. This

connection must be tied externally to all other chip ground connections. The user
must provide adequate external decoupling capacitors.