15 show remotecon, 16 show serial, 17 show snmpcommunity – PLANET WGS3-24240 User Manual
Page 381

User’s Manual of WGS3-24000 / WGS3-24240
381
However it is only required to be unique. When concatenated with dot1dStpPriority a unique BridgeIdentifier is formed
which is used in the Spanning Tree Protocol.
▫
MAC Address Type - Specifies which MAC address should be used for in-band connectivity. The choices are the burned
in or the Locally Administered address. The factory default is to use the burned in MAC address.
▫
Network Configuration Protocol Current - Indicates which network protocol is being used. The options are bootp | dhcp
| none.
▫
Java Mode - Specifies if the switch should allow access to the Java applet in the header frame. Enabled means the applet
can be viewed. The factory default is disabled.
▫
Management VLAN ID - Specifies the management VLAN ID.
8.5.15 show remotecon
This command displays telnet settings.
▫
Format show remotecon
▫
Mode
Privileged EXEC and User EXEC
Remote Connection Login Timeout (minutes) - This object indicates the number of minutes a remote connection session is
allowed to remain inactive before being logged off. A zero means there will be no timeout. This may be specified as a number
from 0 to 160. The factory default is 5.
Maximum Number of Remote Connection Sessions - This object indicates the number of simultaneous remote connection
sessions allowed. The factory default is 5.
Allow New Telnet Sessions - Indicates that new telnet sessions will not be allowed when set to no. The factory default value is
yes.
8.5.16 show serial
This command displays serial communication settings for the switch.
▫
Format show
serial
▫
Mode
Privileged EXEC and User EXEC
Serial Port Login Timeout (minutes) - Specifies the time, in minutes, of inactivity on a Serial port connection, after which the
Switch will close the connection. Any numeric value between 0 and 160 is allowed, the factory default is 5. A value of 0 disables
the timeout.
Baud Rate - The default baud rate at which the serial port will try to connect. The available values are 1200, 2400, 4800, 9600,
19200, 38400, 57600, and 115200 baud. The factory Default is 9600 baud.
Character Size - The number of bits in a character. The number of bits is always 8.
Flow Control - Whether Hardware Flow-Control is enabled or disabled. Hardware Flow Control is always disabled.
Stop Bits - The number of Stop bits per character. The number of Stop bits is always 1.
Parity Type - The Parity Method used on the Serial Port. The Parity Method is always None.
8.5.17 show snmpcommunity
This command displays SNMP community information.
Six communities are supported. You can add, change, or delete communities. The switch does not have to be reset for changes