4.6.3.2 RIP Interface Summary
Figure 4-6-10 RIP Interface Summary
Non-Configurable Data
Object
Description
• Slot/Port
The slot and port for which the information is being displayed.
• IP Address
The IP Address of the router interface.
• Send Version
The RIP version to which RIP control packets sent from the interface conform.
The value is one of the following:
•
RIP-1 - RIP version 1 packets will be sent using broadcast.
•
RIP-1c - RIP version 1 compatibility mode. RIP version 2 formatted
packets will be transmitted using broadcast.
•
RIP-2 - RIP version 2 packets will be sent using multicast.
•
None - RIP control packets will not be transmitted.
The default is RIP-2.
• Receive Version
Which RIP version control packets will be accepted by the interface. The value is
one of the following:
•
RIP-1 - only RIP version 1 formatted packets will be received.
•
RIP-2 - only RIP version 2 formatted packets will be received.
•
Both - packets will be received in either format.
•
None - no RIP control packets will be received.
The default is Both.
• RIP Admin Mode
Whether RIP is enabled or disabled on the interface.
• Link State
Whether the RIP interface is up or down.
• Refresh button
Refresh the data on the screen with the present state of the data in the switch.