PLANET WGS3-24240 User Manual
Page 131
User’s Manual of WGS3-24000 / WGS3-24240
131
The factory default is 20 centiseconds (0.2 seconds).
• Leave Time
(centiseconds)
Specifies the time to wait after receiving an unregister request for a VLAN or
multicast group before deleting the associated entry, in centiseconds. This allows
time for another station to assert registration for the same attribute in order to
maintain uninterrupted service. An instance of this timer exists for each GARP
participant for each port. Permissible values are 20 to 600 centiseconds (0.2 to
6.0 seconds).
The factory default is 60 centiseconds (0.6 seconds).
• Leave All Time
(centiseconds)
This Leave All Time controls how frequently LeaveAll PDUs are generated. A
LeaveAll PDU indicates that all registrations will shortly be deregistered.
Participants will need to rejoin in order to maintain registration. An instance of this
timer exists for each GARP participant for each port. The Leave All Period Timer
is set to a random value in the range of LeaveAllTime to 1.5*LeaveAllTime.
Permissible values are 200 to 6000 centiseconds (2 to 60 seconds).
The factory default is 1000 centiseconds (10 seconds).
4.3.4.2 GARP Switch Configuration
This page is to Enable/Disable GVRP and GMRP mode. Note that it can take up to 10 seconds for GARP configuration changes
to take effect.
Figure 4-3-17 GARP Switch Configuration
Object
Description
• GVRP Mode
Choose the GARP VLAN Registration Protocol administrative mode for the
switch by selecting enable or disable from the pull-down menu. The factory
default is disabled.
• GMRP Mode
Choose the GARP Multicast Registration Protocol administrative mode for the
switch by selecting enable or disable from the pull-down menu. The factory
default is disabled.