12 position display types, 13 unit of measurement – HEIDENHAIN TNC 426B (280 472) ISO programming User Manual
Page 346

HEIDENHAIN TNC 410, TNC 426, TNC 430
331
13.12 Position Display Types
In the Manual Operation mode and in the program run modes of
operation, you can select the type of coordinates to be displayed.
The figure at right shows the different tool positions:
Starting position
Target position of the tool
Workpiece datum
Machine datum
The TNC position displays can show the following coordinates:
Function
Display
Nominal position: the value presently commanded
by the TNC
NOML.
Actual position; current tool position
ACTL.
Reference position: the actual position as referenced
REF
to the machine datum
Distance remaining to the programmed position;
DIST.
difference between actual and target positions
Servo lag: difference between nominal and actual positions LAG
Deflection of the measuring touch probe
DEFL.
Traverses that were carried out with
M118
handwheel superpositioning (M118)
(only position display 2, not TNC 410)
With the MOD function Position display 1 you can select the
position display in the status display. With Position display 2
you can select the position display in the additional status display.
13.13 Unit of Measurement
This MOD function determines whether the coordinates are
displayed in millimeters (metric system) or inches.
■
To select the metric system (e.g. X = 15.789 mm) set the Change
mm/inches function to mm. The value is displayed with 3 digits
after the decimal point.
■
To select the inch system (e.g. X = 0.6216 inch) set the Change
mm/inches function to inches. The value is displayed to 4 decimal
places.
NOML.
ACTL.
LAG
REF
DIST.
13.12 Selecting the P
osition Displa
y;
13.13 Selecting the Unit of Measur
e
Pkap13.pm6
29.06.2006, 08:07
331