2 t ool d ata – HEIDENHAIN TNC 426B (280 472) ISO programming User Manual

Page 101

background image

85

HEIDENHAIN TNC 410, TNC 426, TNC 430

Additional notes on tool tables
Machine parameter 7266.x defines which data can be entered in
the tool table and in what sequence the data is displayed. Note
when configuring the tool table that the total width cannot be more
than 250 characters. Wider tables cannot be transferred over the
interface. The width of the individual columns is given in the
description of MP7266.x.

You can overwrite individual columns or lines of a tool
table with the contents of another file. Prerequisites:

The target file must exist.

The file to be copied must contain only the columns
(or lines) you want to replace.

To copy individual columns or lines, press the REPLACE
FIELDS soft key (see 4.4 Enhanced File Management for
the TNC 426, TNC 430).

5.2 T

ool D

ata

Fkap5.pm6

29.06.2006, 08:06

85