beautypg.com

HEIDENHAIN TNC 426B (280 472) ISO programming User Manual

Page 333

background image

13 MOD Functions

318

13.6 Setting Up the Data Interfaces for

TNC 426, TNC 430

Press the soft key marked RS 232 / RS 422 SETUP to call a menu for
setting the data interfaces:

Setting the RS-232 interface

The mode of operation and baud rates for the RS-232 interface are
entered in the upper left of the screen.

Setting the RS-422 interface

The mode of operation and baud rates for the RS-422 interface are
entered in the upper right of the screen.

Setting the OPERATING MODE of the external
device

The functions “Transfer all files,” “Transfer selected file,”
and “Transfer directory” are not available in the
operating modes FE2 and EXT.

Setting the BAUD RATE

You can set the BAUD-RATE (data transfer speed) from 110 to
115,200 baud.

External device

Operating mode Symbol

HEIDENHAIN floppy disk units
FE 401 B

FE1

FE 401 from prog. no. 230 626 03

FE1

HEIDENHAIN floppy disk unit

FE2

FE 401 up to prog. no. 230 626 02

PC with HEIDENHAIN data transfer

FE1

Software TNCremo

Non-HEIDENHAIN devices such as

EXT1, EXT2

Punchers, PC without TNCremo

PC with HEIDENHAIN software

LSV2

TNCremo for remote operation
of the TNC

13.6 Set

ting Up the D

ata Int

erf

aces f

o

r

TNC 426,

TNC 430

Pkap13.pm6

29.06.2006, 08:06

318