133

HEIDENHAIN TNC 410, TNC 426, TNC 430

Input
If you enter M120 in a positioning block, the TNC continues the
dialog for this block by asking you the number of blocks LA that are
to be calculated in advance.

Effect
M120 must be located in an NC block that also contains radius
compensation RL or RR. M120 is then effective from this block until

radius compensation is canceled, or

M120 LA0 is programmed, or

M120 is programmed without LA.

Call another program with %...

M120 becomes effective at the start of block.

Constraints (only for TNC 426, TNC 430)

After an external or internal stop, you can only re-enter the
contour with the function RESTORE POS. AT N.

If you are using the path functions G25 and G24, the blocks
before and after G25 or CHF must contain only coordinates of the
working plane.

Superimposing handwheel positioning during
program run: M118 (not TNC 410)

Standard behavior
In the program run modes, the TNC moves the tool as defined in
the part program.

Behavior with M118
M118 permits manual corrections by handwheel during program
run. You can use this miscellaneous function by entering axis-
specific values X, Y and Z (in mm) behind M118.

Programming M118

If you enter M118 in a positioning block, the TNC continues the
dialog for this block by asking you the axis-specific values. The
coordinates are entered with the orange axis direction buttons or
the ASCII keyboard.

Effect
Cancel handwheel positioning by programming M118 once again
without X, Y and Z.

M118 becomes effective at the start of block.

7.4 Miscellaneous F

unctions f

or Cont

our

ing Beha

vior

Example NC block
You wish to be able to use the handwheel during
program run to move the tool in the working plane
X/Y by ±1 mm of the programmed value:

G01 G41 X+0 Y+38,5 F125 M118 X1 Y1

M118 is always effective in the original
coordinate system, even if the working
plane is tilted!

M118 also functions in the Positioning
with MDI mode of operation!

If M118 is active, the MANUAL OPERATI-
ON function is not available after a
program interruption

Hkap7.pm6

29.06.2006, 08:06

133