HEIDENHAIN TNC 426B (280 472) ISO programming User Manual
Page 334

HEIDENHAIN TNC 410, TNC 426, TNC 430
319
ASSIGN
This function sets the destination for the transferred data.
Applications:
• Transferring values with Q parameter function D15
• Path on the TNC’s hard disk in which the digitized data are stored
The TNC mode of operation determines whether the PRINT or
PRINT TEST function is used:
TNC mode of operation
Transfer function
Program Run, Single Block
Program Run, Full Sequence
Test run
PRINT TEST
You can set PRINT and PRINT TEST as follows:
Function
Path
Output data via RS-232
RS232:\....
Output data via RS-422
RS422:\....
Save data to the TNC’s hard disk
TNC:\....
Save data in directory in which the program
with D15 or the program with the
digitizing cycles is located
- vacant -
File names
Data
Operating mode
File name
Digitizing data
Program Run
Defined in the RANGE
cycle
Values with FN15
Program Run
%D15RUN.A
Values with FN15
Test run
%D15SIM.A
13.6 Set
ting Up the D
ata Int
erf
aces f
o
r
TNC 426,
TNC 430
Pkap13.pm6
29.06.2006, 08:06
319