HEIDENHAIN TNC 426B (280 472) ISO programming User Manual
Page 282

HEIDENHAIN TNC 410, TNC 426, TNC 430
267
Overlap factor: Q112
The overlap factor for pocket milling (MP7430) is assigned to Q112.
Unit of measurement for dimensions in the program: Q113
The value of parameter Q113 specifies whether the highest-level
NC program (for nesting with %...) is programmed in millimeters or
inches.
Dimensions of the main program
Parameter value
Metric system (mm)
Q113 = 0
Inch system (inches)
Q113 = 1
Tool length: Q114
The current value for the tool length is assigned to Q114.
Coordinates after probing during program run
The parameters Q115 to Q119 contain the coordinates of the
spindle position at the moment of contact during programmed
measurement with the 3-D touch probe.
The length and radius of the probe tip are not compensated in
these coordinates.
Coordinate axis
Parameter
X axis
Q115
Y axis
Q116
Z axis
Q117
IVth axis
Q118
Vth axis (not TNC 410)
Q119
Deviation between actual value and nominal value during
automatic tool measurement with the TT 120 (only
conversational dialog)
Actual-nominal deviation
Parameter
Tool length
Q115
Tool radius
Q116
Tilting the working plane with mathematical angles: Rotary axis
coordinates calculated by the TNC (not TNC 410)
Coordinates
Parameter
A axis
Q120
B axis
Q121
C axis
Q122
1
0.9 Pr
eassigned Q P
a
ra
met
ers
Mkap10.pm6
29.06.2006, 08:06
267