beautypg.com

HEIDENHAIN TNC 426B (280 472) ISO programming User Manual

Page 282

background image

HEIDENHAIN TNC 410, TNC 426, TNC 430

267

Overlap factor: Q112
The overlap factor for pocket milling (MP7430) is assigned to Q112.

Unit of measurement for dimensions in the program: Q113
The value of parameter Q113 specifies whether the highest-level
NC program (for nesting with %...) is programmed in millimeters or
inches.

Dimensions of the main program

Parameter value

Metric system (mm)

Q113 = 0

Inch system (inches)

Q113 = 1

Tool length: Q114
The current value for the tool length is assigned to Q114.

Coordinates after probing during program run
The parameters Q115 to Q119 contain the coordinates of the
spindle position at the moment of contact during programmed
measurement with the 3-D touch probe.

The length and radius of the probe tip are not compensated in
these coordinates.

Coordinate axis

Parameter

X axis

Q115

Y axis

Q116

Z axis

Q117

IVth axis

Q118

Vth axis (not TNC 410)

Q119

Deviation between actual value and nominal value during
automatic tool measurement with the TT 120 (only
conversational dialog)

Actual-nominal deviation

Parameter

Tool length

Q115

Tool radius

Q116

Tilting the working plane with mathematical angles: Rotary axis
coordinates calculated by the TNC (not TNC 410)

Coordinates

Parameter

A axis

Q120

B axis

Q121

C axis

Q122

1

0.9 Pr

eassigned Q P

a

ra

met

ers

Mkap10.pm6

29.06.2006, 08:06

267