227

HEIDENHAIN TNC 410, TNC 426, TNC 430

8.9 Coor

dinat

e

T

ransf

or

mation Cy

cles

With the function „Actual position capture“ the TNC
stores the position of that axis in the header of the table
which is above the marked value (not TNC 410).

Configuring datum tables (not TNC 410)
On the second and third soft-key rows you can define for each
datum table the axes for which you wish to set the datums. In the
standard setting all of the axes are active. If you wish to exclude an
axis, set the corresponding soft key to OFF. The TNC then deletes
that column from the datum table.

To leave a datum table
Select a different type of file in file management and choose the
desired file.

Activating a datum table for program run (TNC 410)
With the TNC 410 you must use the function %:TAB: in the NC
program to select the datum table from which the TNC is to take
the datums:

ú

To select the functions for program call, press the
PGM CALL key.

ú

Press the DATUM TABLE soft key.

ú

Enter the name of the datum table, then confirm with
the END key.

Example NC block:

N72 %:TAB: “NAMES“*

Activating a datum table for program run (TNC 426, TNC 430)
With the TNC 426, TNC 430 you must manually activate the datum
table in a program run mode of operation:

ú

Select a program run mode, e.g., Program Run, Full
Sequence

ú

To call the file manager, press the PGM MGT key —
see also section 4 “File Management” for more
information.

ú

To select an already existing datum table, move the
highlight to the desired table and confirm with the
ENT key. The TNC indicates with M the selected table
in the status field.

Kkap8.pm6

29.06.2006, 08:06

227