2 mounting the switch in cabinet, 2 mounting the switch in cabinet -6 – H3C Technologies H3C S9500 Series Switches User Manual
Page 75

Installation Manual
H3C S9500 Series Routing Switches
Chapter 4 Switch Installation
4-6
S9512 17U
(1) Blank filler panel
(2) Cabling frame
(3) Backward cabling frame
(4) External PoE power supply slot (or reserved)
Figure 4-5 One S9512 chassis in a cabinet
Guideline: The space marked in Figure 4-5must be reserved, and the remaining is at
your disposal.
4.3.2 Mounting the Switch in Cabinet
Step 1: Confirm before installation
z
Make sure that the cabinet has been well fixed. The layout inside the cabinet for
switch installation has been well done and there is no obstruction inside or around
the cabinet.
z
Make sure that the switch is ready for installation and has been carried to a place
convenient for further moving near the cabinet.
Step 2: Mount a shelf inside the cabinet depending on the position where you want to
put the switch.
Step 3: Install the cabling rack and attach the mounting ears shipped with the switch
onto the switch.
Step 4: Carry the switch at both sides with another person to the place in front of the
cabinet slowly.
Step 5: Lift the switch a little higher than the cabinet shelf, put it on the shelf, and push
it into the cabinet.
- H3C S7500E Series Switches H3C S7500 Series Switches H3C S5800 Series Switches H3C S5820X Series Switches H3C S5500 Series Switches H3C S5120 Series Switches H3C S3610[S5510] Series Switches H3C S3600 Series Switches H3C S3100 Series Switches OAA For Routers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSQM1WCMB0 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C WA2600 Series WLAN Access Points H3C WA2200 Series WLAN Access Points H3C SecPath F1000-E H3C SecPath F1000-A H3C SecPath F1000-S H3C SecPath F100-A H3C SecPath F100-C-EI H3C SecPath V100-E H3C SecCenter iTAS H3C Device Manager