beautypg.com

H3C Technologies H3C S9500 Series Switches User Manual

Page 21

background image

Installation Manual
H3C S9500 Series Routing Switches

Chapter 1 Product Overview

1-15

4) RESET

button

You can press the RESET button on the panel to reset the SRP1N4 module.

5) Status LEDs

z

CF status LED

You can learn the operating status of the CF card by reading the CF status LED on the
panel.

Table 1-12

CF status LED

LED

Status

ON

The CF card is in position and is idle. You cannot remove
the card.

Blinking

The CF card is in position and reading/writing data. You
cannot remove the card.

CFS

OFF

The CF card is out of position or offline (you can force the
in-position CF card to go offline using the appropriate
background command). You can remove/insert the card.

z

Status LEDs for LPU modules

The SRP1N4 module has 12 pairs of LEDs to indicate the operating status of 12 LPU
modules.

Table 1-13

Status LEDs for LPU modules

LED

Status

ON

The module is faulty.

OFF

The module is faulty or out of position.

Blinking (1s)

The module is running normally.

RUN

Fast blinking (125
ms)

The module is booting or not registered
successfully.

ON

The module has alarms.

ALM

OFF

The module has no alarms or is out of position.

0~5, 8~13

Indicate slots 0 through 5 and slots 8 through 13

z

Status LEDs for the SRP1N4 module

You can learn the operating status of SRP1N4 module by reading the SFS, ACT, ALM
and RUN LEDs on it. The following table gives a summary of the four LEDs.