Ii. for s9505 – H3C Technologies H3C S9500 Series Switches User Manual
Page 10

Installation Manual
H3C S9500 Series Routing Switches
Chapter 1 Product Overview
1-4
II. For S9505
SRPU
LPU
LPU
LPU
LPU
Fa
n tr
ay
LPU
AC or DC power
SRPU
AC or DC power
PoE
entry
SRPU
LPU
LPU
LPU
LPU
Fa
n tr
ay
LPU
AC or DC power
SRPU
AC or DC power
PoE
entry
Figure 1-6
S9505 slots
All modules in the cabinet are hot-swappable.
z
The S9505 chassis provides seven slots: The top two accommodate SRPU
modules, which are in 1+1 redundancy; the remaining five accommodate LPU
modules and service processor cards, which can be hybrid.
z
At the bottom of the chassis is the power supply area that contains one PoE entry
area, two power supply units (PSU) that are online-swappable (which means you
can use one PSU to supply power to the whole switch while changing the other
PSU). The switch can be either AC-powered or DC-powered.
z
On the right of the chassis is the fan area that contains only one vertical fan tray.
The fan tray draws air from the left and exhausts on the right.
Note:
The two PSUs are online-swappable. But before removing or inserting a PSU, you must
first power off the PSU.
- H3C S7500E Series Switches H3C S7500 Series Switches H3C S5800 Series Switches H3C S5820X Series Switches H3C S5500 Series Switches H3C S5120 Series Switches H3C S3610[S5510] Series Switches H3C S3600 Series Switches H3C S3100 Series Switches OAA For Routers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSQM1WCMB0 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C WA2600 Series WLAN Access Points H3C WA2200 Series WLAN Access Points H3C SecPath F1000-E H3C SecPath F1000-A H3C SecPath F1000-S H3C SecPath F100-A H3C SecPath F100-C-EI H3C SecPath V100-E H3C SecCenter iTAS H3C Device Manager