2 hardware maintenance, 1 replacing ac psu, I. removing ac psu (s9505 as example) – H3C Technologies H3C S9500 Series Switches User Manual
Page 113: 2 hardware maintenance -4, 1 replacing ac psu -4
Installation Manual
H3C S9500 Series Routing Switches
Chapter 6 Switch Monitoring and Maintenance
6-4
6.2 Hardware Maintenance
6.2.1 Replacing AC PSU
Caution:
The PSU of the S9500 series is hot-swappable.
When installing or replacing a PSU while power is being supplied, you must take care in
the operation procedures and safety with electricity. Do not touch any naked wires,
terminals or any parts of the product marked with a dangerous voltage label to avoid
bodily injury.
I. Removing AC PSU (S9505 as example)
Step 1: Put the power switch on the PSU from the ON position into the OFF position.
Step 2: Pull right the clamp holding the power cord connector and unplug the power
cord.
Step 3: Unscrew the captive screws on the both sides of the PSU panel with a Phillips
screwdriver.
Step 4: Remove the air filter from the PSU.Hold the handle of the PSU and pull the PSU
gently out of the chassis along the guides.
Figure 6-1 Remove and install the AC PSU
You can remove the AC PSU on the S9502,S9508 and S9512 in the same way as on
the S9505.
- H3C S7500E Series Switches H3C S7500 Series Switches H3C S5800 Series Switches H3C S5820X Series Switches H3C S5500 Series Switches H3C S5120 Series Switches H3C S3610[S5510] Series Switches H3C S3600 Series Switches H3C S3100 Series Switches OAA For Routers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSQM1WCMB0 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C WA2600 Series WLAN Access Points H3C WA2200 Series WLAN Access Points H3C SecPath F1000-E H3C SecPath F1000-A H3C SecPath F1000-S H3C SecPath F100-A H3C SecPath F100-C-EI H3C SecPath V100-E H3C SecCenter iTAS H3C Device Manager