beautypg.com

Delta Electronics AC Motor Drive VFD-E User Manual

Page 80

background image

Chapter 4 Parameters|

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

4-27

Parameter Explanation

Settings

Factory

Setting

Customer

0: No function

1: AC drive operational

2: Master frequency attained

11.00

Multi-function
Output Terminal
MO2/RA2

3: Zero speed

0

4: Over torque detection

5: Base-Block (B.B.) indication

6: Low-voltage indication

11.01

Multi-function
Output Terminal
MO3/RA3

7: Operation mode indication

0

8: Fault indication

9: Desired frequency 1 attained

10: Terminal count value attained

11.02

Multi-function
Output Terminal
MO4/RA4

11: Preliminary count value attained

0

12: Over Voltage Stall supervision

13: Over Current Stall supervision

14: Heat sink overheat warning

11.03

Multi-function
Output Terminal
MO5/RA5

15: Over Voltage supervision

0

16: PID supervision

17: Forward command

18: Reverse command

11.04

Multi-function
Output Terminal
MO6/RA6

19: Zero speed output signal

0

20: Warning(FbE,Cexx, AoL2, AUE, SAvE)

21: Brake control (Desired frequency

attained)

0

22: Drive ready

11.05

Multi-function
Output Terminal
MO7/RA7

23: Desired frequency 2 attained

0: No function

0

1: Multi-Step speed command 1

11.06

Multi-function Input
Terminal (MI7)

2: Multi-Step speed command 2

3: Multi-Step speed command 3

0

11.07 Multi-function

Input

Terminal (MI8)

4: Multi-Step speed command 4