B.4.2 AC Output Reactor Recommended Value

115V/230V, 50/60Hz, 3-Phase

Inductance (mH)

kW HP

Fundamental

Amps

Max.

continuous

Amps

3% impedance

5% impedance

0.2

1/4 4

4

9

12

0.4

1/2 6

6

6.5

9

0.75

1 8

12

3

5

1.5

2 8

12

1.5

3

2.2

3 12

18

1.25

2.5

3.7

5 18

27

0.8

1.5

5.5

7.5 25

37.5

0.5

1.2

7.5

10 35

52.5

0.4

0.8

460V, 50/60Hz, 3-Phase

Inductance (mH)

kW HP

Fundamental

Amps

Max.

continuous

Amps

3% impedance

5% impedance

0.4

1/2 2

3

20

32

0.75

1

4 6 9

12

1.5

2

4 6 6.5

9

2.2

3

8 12 5

7.5

3.7

5

12 18 2.5

4.2

5.5

7.5

18 27 1.5

2.5

7.5

10

18 27 1.5

2.5

11

15

25 37.5 1.2

2