Appendix D How to Use PLC Function|

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

D-49

X0

M0

M1

M2

ZCP

If C10 < K10, M0 = On

If K10 < C10 < K100, M1 = On

If C10 > K100, M2 = On

X0

K10

C10

M0

K100

=

=

3.

To clear the comparison result, use RST or ZRST instruction.

X0

RST

M0

RST

RST

M1

M2

X0

ZRST

M0

M2

API Mnemonic Operands

Function

12

MOV P

S,

D

Move

Bit Devices

Word devices

Program Steps

Type
OP

X Y M K H

KnX KnY KnM T

C

D

S

*

*

*

*

*

*

*

*

D

*

*

*

*

*

MOV, MOVP: 5 steps

Operands:

S: Source of data D: Destination of data

Explanations:

1.

See the specifications of each model for their range of use.

2.

When this instruction is executed, the content of S will be moved directly to D. When this

instruction is not executed, the content of D remains unchanged.

Program Example:

MOV instruction has to be adopted in the moving of 16-bit data.

1.

When X0 = Off, the content in D10 will remain unchanged. If X0 = On, the value K10 will

be moved to D10 data register.

2.

When X1 = Off, the content in D10 will remain unchanged. If X1 = On, the present value

T0 will be moved to D10 data register.