Chapter 4 Parameters|

4-84

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

04.26

Display the Status of Multi-function Input Terminal

Settings

Read Only

Factory setting: ##

Display

Bit0: MI1 Status

Bit1: MI2 Status

Bit2: MI3 Status

Bit3: MI4 Status

Bit4: MI5 Status

Bit5: MI6 Status

Bit6: MI7 Status

Bit7: MI8 Status

Bit8: MI9 Status

Bit9:

MI10

Status

Bit10:

MI11

Status

Bit11:

MI12

Status

The multi-function input terminals are falling-edge triggered. For standard AC motor drive

(without extension card), there are MI1 to MI6 and Pr.04.26 will display 63 (111111) for no

action.

1

2

3

4

5

0

0=Active

1=off

MI1
MI2

MI3
MI4
MI5
MI6

Weights
Bit

For

Example:

If Pr.04.26 displays 52, it means MI1, MI2 and MI4 are active.

The display value 52= 32+16+4 =1 X 2

5

+ 1X 2

4

+ 1X 2

2

= bit 6 X 2

5

+ bit 5 X 2

4

+ bit 3 X 2

2