beautypg.com

Delta Electronics AC Motor Drive VFD-E User Manual

Page 127

background image

Chapter 4 Parameters|

4-74

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

01.00=60.00 Hz

AVI

ACI

analog input

04.14=70

04.18=50

04.12=30

04.16=0

04.11=0V 04.15=4mA

04.13=10V
04.17=20mA

04.04

Multi-function Input Terminal (MI1, MI2) 2-wire/ 3-wire Operation Control Modes

Factory Setting: 0

Settings

0

2-wire: FWD/STOP, REV/STOP

1 2-wire:

FWD/REV,

RUN/STOP

2 3-wire

Operation

There are three different types of control modes:

04.04

External Terminal

0

2-wire

FWD /STOP

REV / STOP

VFD-E

MI1:("OPEN":STOP)

("CLOSE":FWD)

MI2:("OPEN": STOP)

("CLOSE": REV)

DCM

FWD/STOP

REV/STOP

1

2-wire

FWD/ REV

RUN / STOP

VFD-E

MI1:("OPEN":STOP)

("CLOSE":RUN)

MI2:("OPEN": FWD)

("CLOSE": REV)

DCM

RUN/STOP

FWD/REV