Chapter 4 Parameters|

4-18

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

Parameter Explanation

Settings

Factory

Setting

Customer

10: Current exceeds 2 times rated current
during decel.(ocd)

11: Current exceeds 2 times rated current
during steady state operation (ocn)

12: Ground fault (GFF)

13:

Reserved

14:

Phase-Loss

(PHL)

15:

Reserved

16: Auto Acel/Decel failure (CFA)

17: SW/Password protection (codE)

18: Power Board CPU WRITE failure (cF1.0)

19: Power Board CPU READ failure (cF2.0)

06.10

Third Most Recent
Fault Record

20: CC, OC Hardware protection failure
(HPF1)

21: OV Hardware protection failure (HPF2)

22: GFF Hardware protection failure (HPF3)

06.11

Fourth Most Recent
Fault Record

23: OC Hardware protection failure (HPF4)

24: U-phase error (cF3.0)

25: V-phase error (cF3.1)

06.12

Fifth Most Recent
Fault Record

26: W-phase error (cF3.2)

27: DCBUS error (cF3.3)

28: IGBT Overheat (cF3.4)

29: Power Board Overheat (cF3.5)

30: Control Board CPU WRITE failure (cF1.1)

31: Control Board CPU WRITE failure (cF2.1)

32: ACI signal error (AErr)

33:

Reserved

34: Motor PTC overheat protection (PtC1)
35-39: Reserved
40: Communication time-out error of control
board and power board (CP10)