Appendix E CANopen Function |

E-10

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

Display

Controller

Error
Code

Description

CANopen

Error

Code

CANopen

Error

Register

(bit 0~7)

0020H

Internal EEPROM can not be read

5530h

7

0021H Analog

signal

error

FF00h

7

0023H

Motor overheat protection

7120h

3

0024H PG

signal

error

7300h

7

0029H Communication time-out error on the

control board or power board

7500h

4

Definition of Index

Index Sub

Definition

Factory

Setting

R/W Size Unit

NOTE

0x1000 0 Abort

connection

option code

0x00010192

RO U32

0x1001 0 Error

register

0 RO U8

0x1005 0

COB-ID SYNC
message

0x80

RW U32

0x1006 0

Communication cycle
period 0

RW U32 us

500us~15000us

0x1008 0

Manufacturer device
name 0

RO U32

0x1009 0

Manufacturer
hardware version

0

RO U32

0x100A 0

Manufacturer software
version 0

RO U32

0x100C

0 Guarding time

0 RW U16 ms

0x80 + node 1

0x100D 0 Guarding

factor

0 RW U8

0x1014 0 COB-ID

emergency

0x0000080

+Node-ID

RO U32

0x1015

0 Inhibit time EMCY

0

RW U16 100us

It is set to be
multiple of 10.

0 Number

0x1 RO U8

0x1016

1

Consumer heartbeat
time

0x0 RW U32 1ms

Heartbeat time can
be used when
Guarding time is
invalid.

0x1017 0

Producer heartbeat
time

0x0 RW U16 1ms

Heartbeat time can
be used when
Guarding time is
invalid.

0 Number

0x3 RO U8

1 Vender

ID

0x000001DD RO U32

2 Product

code

0x00002600

+model

RO U32

0x1018

3 Revision

0x00010000 RO U32

0

Server SDO
Parameter

2

RO U8

0x1200

1

COB-ID Client ->
Server

0x0000600+

Node-ID

RO U32