background image

Chapter 2 Installation and Wiring|

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

2-3

Figure 1 for models of VFD-E Series
VFD002E11A/21A, VFD004E11A/21A, VFD007E21A, VFD002E11C/21C, VFD004E11C/21C,
VFD007E21C, VFD002E11P/21P, VFD004E11P/21P, VFD007E21P

AVI

ACI

ACM

+

+10V

5K

3

2

1

Power supply
+10V 20m A

Master Fr equency
0 to 10V 47K

Analog S ignal Common

E

Main c irc ui t (power) terminals

Contr ol c ircuit ter minals

Shielded l eads & Cable

E

R(L1)

S(L2)

F us e/NF B(None F use Br eaker)

SA

OF F

ON

MC

MC

RB

RC

Recommended Circui t
when power s uppl y

is turned O FF by a
fault output

R(L1)

S(L2)

E

Analog Multi- func tion Output
Ter minal

factory setti ng: Analog fr eq.
/ c ur rent meter

0~1 0VDC/2 mA

U(T1)
V(T2)

W(T3)

IM

3~

AFM

ACM

RA

RB

RC

Motor

F ac tor y setting:
Driv e is in oper ation

48V50mA Max.

Multi-function
Photocoulper Output

Analog S ignal common

E

E

MO1

MCM

MI1
MI2
MI3
MI4

MI6

MI5

DCM

+24V

F WD/Stop

REV/Stop

Multi-s tep 1

Multi-s tep 2

Multi-s tep 3

Multi-s tep 4

Digital Si gnal Common

F ac tor y
setting

Sw2

AVI

ACI

F act ory set tin g:
ACI Mode

ACI/AVI sw itch
Wh en switch in g to AVI,

it in dicates AVI2

-

8 1

Sw1

NPN

PNP

F act ory set tin g:
NPN Mode

Please refer to F ig ur e 7
fo r w irin g of NPN

m od e an d PNP
m od e.

BUE

brake unit
( optional)

BR

brake resi stor
(opti onal)

Multi-function c ontact output
Refer to c hapter 2.4 for details .

F ac tor y setting is
malfunction indication

F ac tor y setting: output frequency

4-20mA/0-10V

RS-485 serial inter face
(NO T for VF D*E*C models)

1: Reserv ed
2: EV

5: SG +
6: Reserv ed
7: Reserv ed

8: Reserv ed

3: G ND
4: SG -

F or VFD*E*C mo dels,
p lease ref er t o figu re 8.