beautypg.com

Delta Electronics AC Motor Drive VFD-E User Manual

Page 315

background image

Appendix D How to Use PLC Function|

D-32

Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11

Mnemonic Function

ANI

Series connection- B contact

X0~X17 Y0~Y17

M0~M159 T0~15 C0~C7 D0~D29

Operand

9

9

9

9

9

--

Explanations:

The ANI command is used in the series connection of B contact. The function of the command is to

readout the status of present specific series connection contacts first, and then to perform the “AND”

calculation with the logic calculation result before the contacts, thereafter, saving the result into the

accumulative register.

Program Example:

Ladder diagram:

Command code:

Operation:

LD

X1

Load contact A of X1

ANI

X0

Connect to contact B of
X0 in series

X0

X1

Y1

OUT

Y1

Drive Y1 coil

Mnemonic Function

OR

Parallel connection- A contact

X0~X17 Y0~Y17

M0~M159 T0~15 C0~C7 D0~D29

Operand

9

9

9

9

9

--

Explanations:

The OR command is used in the parallel connection of A contact. The function of the command is to

readout the status of present specific series connection contacts, and then to perform the “OR”

calculation with the logic calculation result before the contacts, thereafter, saving the result into the

accumulative register.