PLC Programming Considerations
Appendix A
A-29
In this example you can use a momentary button identified as TOGGLE
COMMAND to toggle and display between “Select” and “Bypass” for the
station currently selected by the cursor. Another momentary button, labeled
SET COMMAND, activates the toggled command.
You can also modify the command for the station currently selected by
pressing the standard momentary buttons “Manual On” or “Manual Off”.
The PLC uses the Cursor Indicator Address to change the selected station’s
command.
Option Style Number
A Numeric Display Object List displays the style numbers of the currently
visible stations. The values displayed in this list also depend on cursor
movement.
The Numeric Keypad Enable Button allows you to modify the style
number of the selected luxury option station in manual mode.
Assigning Addresses for Object Lists
These tables list the addresses and files used in the example PLC program
for each of the object lists.
The following table displays the addresses for each of the object lists.
Table A.L
Visible State Addresses for the Object Lists
Object List
Visible State
BLK Transfer
Start Address
Number of
Contiguous
Addresses
Number of Bits
per Address
Visible State
PLC Start
Address
ASSEMBLY
STATION
Numeric Display
BO51
5
16
N30:11
LUXURY
OPTION
Local Message
BO56
5
16
N30:16
STATION
STATUS
MultiĆState
Indicator
BO511
5
16
N30:21
OPTION
COMMAND
MultiĆState
Indicator
BO516
5
16
N30:26
OPTION STYLE
NO.
Numeric Display
BO521
5
16
N30:31