beautypg.com

10ć34, The objects chapter 10 – Rockwell Automation 2711 PANELBUILDER SOFTWARE USER MANUAL User Manual

Page 299

background image

The Objects

Chapter 10

10-34

Numeric KeypadĆEnable Button (Keypad Terminals only)

The Numeric Keypad-Enable Button object calls up the Numeric Keypad
window, which is used to enter a numeric value. While the Numeric
Keypad is on screen, the Cancel key, numerics, backspace, decimal point,
sign and Home/Arrow keys (if cursor points have been selected on the
screen) will remain active. All other keys and buttons are disabled.

The Numeric Keypad clears when:

the Cancel key is pressed

the screen changes

the operator cursors to a numeric input cursor point

IMPORTANT: Operator input is disabled for a short time when the
keypad is displayed. This may result in a delay before the first digit can be
entered.

Table 10.K

Numeric KeypadĆEnable Button Formatting and Addressing Options

ББББББ

ББББББ

Format Options

ББББББ

ББББББ

ББББББББ

ББББББББ

ББББББ

ББББББ

Address Options

БББББ

БББББ

Data Types

БББББ

БББББ

Data Range

ББББББ

ББББББ

Decimal Point

ББББББ

ББББББ

Disabled

ББББББББ

ББББББББ

ББББББ

ББББББ

Keypad Control

БББББ

БББББ

Binary

БББББ

БББББ

0 - 65,535

ББББББ

ББББББ

ББББББ

ББББББ

Fixed Position

ББББББББ

ББББББББ

No. of digits after decimal pt.

ББББББ

ББББББ

Address

БББББ

БББББ

BCD

БББББ

БББББ

0 - 99,999,999

ББББББ

ББББББ

ББББББ

ББББББ

PLC Controlled

ББББББББ

ББББББББ

ББББББ

ББББББ

БББББ

БББББ

Signed Integer

БББББ

БББББ

-32,768 - +32,767

ББББББ

ББББББ

ББББББ

ББББББ

Decimal Key Controlled

ББББББББ

ББББББББ

ББББББ

ББББББ

*Decimal Point

Position Address

БББББ

БББББ

Binary

БББББ

БББББ

0 - 7

ББББББ

Б

ББББ

Б

ББББББ

Scratchpad

Operation

ББББББ

Б

ББББ

Б

ББББББ

Retain after ENTER

Remove after ENTER

ББББББББ

Б

ББББББ

Б

ББББББББ

ББББББ

Б

ББББ

Б

ББББББ

#Enter Key Control

Address

БББББ

Б

БББ

Б

БББББ

Bit

БББББ

Б

БББ

Б

БББББ

0 - 1

ББББББ

Б

ББББ

Б

ББББББ

ББББББ

Б

ББББ

Б

ББББББ

ББББББББ

Б

ББББББ

Б

ББББББББ

ББББББ

Б

ББББ

Б

ББББББ

#Enter Key

Handshake

Address

БББББ

Б

БББ

Б

БББББ

Bit

БББББ

Б

БББ

Б

БББББ

0 - 1

*only useful with Decimal Key Controlled and PLC Controlled formats - not necessary otherwise

#optional

A maximum of 8 digits can be displayed in the Numeric Keypad window;
the decimal point and minus sign use one digit each. The data type together
with the number of bits assigned to the Keypad Control Address, a PLC
input address, determine the range of PLC values.

If the data type is a signed integer, the minus key on the terminal’s keypad
is functional. The minus key will toggle the polarity if there are no digits in
the scratchpad.

The Scratchpad Operation option allows you to decide if the numeric
data entry scratchpad is removed or retained after the ENTER key is
pressed.