*Supplement

(1)

(2)

(3)

(4)

(5)

Open (Always appears at the beginning). Goes to the next step (2) after
500msec.

Opens SIO (Serial IO). If under EMG condition, waits till EMG is
released. Goes to the next step (3) if no problem.

Check servo. Initialize the motor processor. Waits 500msec after
initializing, then goes to the next step (4).

Sets up the position data and program data. Waits 500msec after setting,
then goes to the next step (5).

Indicates normal status during power up under stand-by condition.

Each display indicates the "progress status of the initial setting", and it is not an alarm. However, switching the controller
power supply for a very short period of time could cause this process to stop. This is a hardware related problem and nothing
unusual. This problem should be corrected by turning the power back on after 15 seconds or longer.

1.

Super SEL Controller 7 Segment Display