Chapter 5. option – IAI America S-SEL-E User Manual
Page 208
![background image](/manuals/350298/208/background.png)
Page 203
Chapter 5.
Option
1. I/O Card Unit (Model H-103)
Super SEL has as standard equipment, 24
inputs and 24 outputs. No PLC is neces-
sary to control peripherals. The Super
SEL can be expanded with up to 11 Ex-
pansion I/O units for a maximum of 288
inputs and 288 outputs.
Structure: photocoupler insulation. Out-
put supports DC 24V 100mA (recom-
mended value 20-50mA) . For larger
loads and AC loads, a relay may be used.
External DC-24V is necessary.
There is no problem adding additional I/
O cards. To add additional I/O cards to a
previously purchased SEL controller,
please let IAI know the address of the
expansion slot to be used.
External power supply for I/O cards:
Input Signal:
10mA/point
Output Signal:
30mA/point
For Example: 10 input signals/8 output
signals.
10 x 10 + 30 x 8 = 340mA. Provide a DC
24V 0.5A power unit.
±High Speed Input Unit:
Each high speed input unit adds 32 in-
put points but these are included when
considering the maximum number of in-
put points that can be used.
Note: The matrix to the right shows the
second card's port numbers. For the nth
card, the input port number begins from
(N -1) x 24 + 24 and the output port num-
ber begins at (N -1) x 24 + 324.
Pin No.
Category
Port No.
Function
Wire Color
1A
P24
External Power +24V Input
1-Brown
1B
Input
24
User Input
1-Red
2A
25
User Input
1-Orange
2B
26
User Input
1-Yellow
3A
27
User Input
1-Green
3B
28
User Input
1-Blue
4A
29
User Input
1-Purple
4B
30
User Input
1-Gray
5A
31
User Input
1-White
5B
32
User Input
1-Black
6A
33
User Input
2-Brown
6B
34
User Input
2-Red
7A
35
User Input
2-Orange
7B
36
User Input
2-Yellow
8A
37
User Input
2-Green
8B
38
User Input
2-Blue
9A
39
User Input
2-Purple
9B
40
User Input
2-Gray
10A
41
User Input
2-White
10B
42
User Input
2-Black
11A
43
User Input
3-Brown
11B
44
User Input
3-Red
12A
45
User Input
3-Orange
12B
46
User Input
3-Yellow
13A
47
User Input
3-Green
13B
Output
324
User Output
3-Blue
14A
325
User Output
3-Purple
14B
326
User Output
3-Gray
15A
327
User Output
3-White
15B
328
User Output
3-Black
16A
329
User Output
4-Brown
16B
330
User Output
4-Red
17A
331
User Output
4-Orange
17B
332
User Output
4-Yellow
18A
333
User Output
4-Green
18B
334
User Output
4-Blue
19A
335
User Output
4-Purple
19B
336
User Output
4-Gray
20A
337
User Output
4-White
20B
338
User Output
4-Black
21A
339
User Output
5-Brown
21B
340
User Output
5-Red
22A
341
User Output
5-Orange
22B
342
User Output
5-Yellow
23A
343
User Output
5-Green
23B
344
User Output
5-Blue
24A
345
User Output
5-Purple
24B
346
User Output
5-Gray
25A
347
User Output
5-White
25B
N24
External Power Supply 0V
5-Black