Chapter 4. programming – IAI America S-SEL-E User Manual
Page 143

Page 138
Chapter 4. Programming
OUTB (BCD Output)
E x p a n s i o n
c o n d i t i o n
( A N D · O R )
I n p u t
c o n d i t i o n
( I / O · F l a g )
C o m m a n d
P o s t
( O u t p u t p o r t · F l a g )
C o m m a n d
O p e r a n d 1
O p e r a n d 2
O p t i o n a l
O p t i o n a l
O U T B
S t a r t o u t p u t
p o r t · F l a g
N o . o f B C D
d i g i t s
[Function]
Outputs the value in variable register 99 as a BCD value to the designated output port or flag.
* The BCD value is read as 4 x n. (Every four input ports are read as one set) (n: no. of digits in Operand 2)
* The maximum number of digits that can be read is 8 but this requires a consecutive 32 point output port.
[Example]
OUTB
316
2
From output port 316, output 4 x 2.
85
Variable 99
ß
Output port No.
Output port
323
322
321
320
319
318
317
316
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
т