Chapter 1. setting up – IAI America S-SEL-E User Manual
Page 11
![background image](/manuals/350298/11/background.png)
Page 9
Please use a dedicated and insulated power transformer when the system has a 240V power source.
Chapter 1. Setting Up
Wiring Notes
1.
To reduce noise problems, the AC117V and the DC24V external power cable should be a twisted pair.
2.
Isolate the SEL cables from the power line.
3.
For DC motors, isolate the encoder cable from the motor cable.
4.
For AC motors, the motor and encoder cables are partially wired together but when the length of the cable
extends more than 5m, please wire them separately.
5.
Consult with IAI if you need to extend the motor and encoder cables beyond the length that comes with the
controller.
AC 117V
AC 240V
Main power
source
Main power
source
240V
240V
1
17V
117V
IA
power
IA
power
Other
power
Other
power
Main
circuit
Other
devices
117V
devices
240V
devices
IA Controller
IA Controller