beautypg.com

Output:range, Output:range -62 – RIGOL DP832A User Manual

Page 86

background image

RIGOL

Chapter 2 Command System

2-62

DP800 Programming Guide

:OUTPut:RANGe

Syntax

:OUTPut:RANGe {P20V|P40V|LOW|HIGH}
:OUTPut:RANGe?

Description

Select the current range of the channel.
Query the range currently selected of the channel.

Parameter

Name

Type

Range

Default

{P20V|P40V|LOW|HIGH}

Discrete

P20V|P40V|LOW|HIGH

P20V

Explanation

 This command is only applicable to single-channel model (DP811A/DP811).

 P20V or LOW represents Range1: 20V/10A and P40V or HIGH represents

Range2: 40V/5A.

 You can also send the

[:SOURce[]]:VOLTage:RANGe

command to select

the current range.

Return Format

The query returns the rated voltage and current values of the range selected, for

example, 20V/10A。

Example

:OUTP:RANG P20V /*Select Range1: 20V/10A as the current range*/
:OUTP:RANG? /*Query the range currently selected and the query returns

20V/10A*/

:OUTP:RANG HIGH /*Select Range2: 40V/5A as the current range*/
:OUTP:RANG? /*Query the range currently selected and the query returns

40V/5A*/

Related

Command

[:SOURce[]]:VOLTage:RANGe

This manual is related to the following products: