Memory commands, Memory[:state]:delete, Memory commands -37 – RIGOL DP832A User Manual
Page 61: Memory[:state]:delete -37
RIGOL
DP800 Programming Guide
2-37
:MEMory Commands
The :MEMory commands are used to save the file to the specified location in the internal memory and
delete, read, lock or unlock the file stored in the specified storage location in the internal memory. DP800
allows the following four kinds of files to be saved in the internal memory.
1. State File (RSF): store the current system state, including the voltage, current, OVP, OCP and track
function status of each channel as well as the system parameters.
2. Record File (ROF): store the output state, voltage, current and power of each channel when the
recorder is enabled (for the channel of which the output is disabled, the corresponding recorded data
will be 0).
3. Timer File (RTF): store the timer parameters edited (the voltage, current and time of each group of
parameters).
4. Delay File (RDF): store the delayer parameters edited (the state and time of each group of
parameters).
Command List:
:MEMory[:STATe]:DELete
Syntax
:MEMory[:STATe]:DELete {RSF|ROF|RTF|RDF},{1|2|3|4|5|6|7|8|9|10}
Description
Delete the file stored in the specified location in the internal memory, including
state file (RSF), record file (ROF), timer file (RTF) and delay file (RDF).
Parameter
Name
Type
Range
Default
{RSF|ROF|RTF|RDF}
Discrete
RSF|ROF|RTF|RDF
None
{1|2|3|4|5|6|7|8|9|10}
Discrete
1|2|3|4|5|6|7|8|9|10
None
Explanation
The internal memory of DP800 series power supply can store at most 10 state
files, 10 record files, 10 timer files and 10 delay files respectively.
This command is only available when a file has been stored in the specified
storage location and the file is not locked (
).
{1|2|3|4|5|6|7|8|9|10} represent the files stored in the corresponding
locations in the internal memory respectively.
Example
:MEM:DEL RSF,5 /*Delete the file currently stored in storage location 5 of state
files in the internal memory*/
Related
Command