beautypg.com

Analyzer:starttime, Analyzer:value, Analyzer:starttime -7 – RIGOL DP832A User Manual

Page 31: Analyzer:value? -7

background image

Chapter 2 Command System

RIGOL

DP800 Programming Guide

2-7

:ANALyzer:STARTTime

Syntax

:ANALyzer:STARTTime {|MINimum|MAXimum}
:ANALyzer:STARTTime? [MINimum|MAXimum]

Description

Set the start time of the analyzer.
Query the start time of the analyzer.

Parameter

Name

Type

Range

Default

Integer

Record period of the record

file opened to end time

Record period of the

record file opened

Explanation

 You can only set the start time when valid record file is opened (refer to

the

:ANALyzer:FILE?

command).

 Send the

:ANALyzer:ANALyze

command and the analyzer analyzes the

recorded data between the start time and end time.

Return Format

The query returns an integer, for example, 1.

Example

:ANAL:STARTT 1 /*Set the start time to 1s*/
:ANAL:STARTT? /*Query the current start time and the query returns 1*/

Related

Commands

:ANALyzer:ANALyze
:ANALyzer:FILE?
:ANALyzer:ENDTime

:ANALyzer:VALue?

Syntax

:ANALyzer:VALue?

Description

Query the voltage, current and power at the specified time in the record file

opened.

Parameter

Name

Type

Range

Default

Integer

Start time of the record file

opened to end time

None

Explanation

This command is only valid when valid record file is opened (refer to

the

:ANALyzer:FILE?

command).

Return Format

The query returns the voltage, current and power separated by commas, for

example, Volt:1.2817V,Curr:0.0485A,Power:0.0622W.

Example

:ANAL:VAL? 5 /*Query the voltage, current and power at 5s of the record file

opened and the query returns

Volt:1.2817V,Curr:0.0485A,Power:0.0622W*/

Related

Commands

:ANALyzer:ENDTime
:ANALyzer:FILE?
:ANALyzer:STARTTime

This manual is related to the following products: