Analyzer:starttime, Analyzer:value, Analyzer:starttime -7 – RIGOL DP832A User Manual
Page 31: Analyzer:value? -7
RIGOL
DP800 Programming Guide
2-7
:ANALyzer:STARTTime
Syntax
:ANALyzer:STARTTime {
:ANALyzer:STARTTime? [MINimum|MAXimum]
Description
Set the start time of the analyzer.
Query the start time of the analyzer.
Parameter
Name
Type
Range
Default
Integer
Record period of the record
file opened to end time
Record period of the
record file opened
Explanation
You can only set the start time when valid record file is opened (refer to
command and the analyzer analyzes the
recorded data between the start time and end time.
Return Format
The query returns an integer, for example, 1.
Example
:ANAL:STARTT 1 /*Set the start time to 1s*/
:ANAL:STARTT? /*Query the current start time and the query returns 1*/
Related
Commands
:ANALyzer:ANALyze
:ANALyzer:FILE?
:ANALyzer:ENDTime
:ANALyzer:VALue?
Syntax
:ANALyzer:VALue?
Description
Query the voltage, current and power at the specified time in the record file
opened.
Parameter
Name
Type
Range
Default
Integer
Start time of the record file
opened to end time
None
Explanation
This command is only valid when valid record file is opened (refer to
Return Format
The query returns the voltage, current and power separated by commas, for
example, Volt:1.2817V,Curr:0.0485A,Power:0.0622W.
Example
:ANAL:VAL? 5 /*Query the voltage, current and power at 5s of the record file
opened and the query returns
Volt:1.2817V,Curr:0.0485A,Power:0.0622W*/
Related
Commands
:ANALyzer:ENDTime
:ANALyzer:FILE?
:ANALyzer:STARTTime