:OUTPut:OVP:CLEAR

Syntax

:OUTPut:OVP:CLEAR [CH1|CH2|CH3]

Description

Clear the label of the overvoltage protection occurred on the specified channel.

Parameter

Name

Type

Range

Default

[CH1|CH2|CH3]

Discrete

CH1|CH2|CH3

None

Explanation

 Before executing the command, make sure that the reason that causes the

OVP on the specified channel is cleared (you can decrease the output voltage

to be below the OVP value or increase the OVP value to be greater than the

output voltage).

 When [CH1|CH2|CH3] is omitted, the system clears the label of the OVP

occurred on the current channel.

 You can also send the

[:SOURce[]]:VOLTage:PROTection:CLEar

command

to clear the circuit and label of the OVP occurred on the specified channel and

turn on the corresponding channel output.

 You can send the

:OUTPut:OVP:ALAR?

or

:OUTPut:OVP:QUES?

command to

query whether OVP occurred on the specified channel.

Example

:OUTP:OVP:QUES? CH1 /*Query whether overvoltage protection currently

occurred on CH1 and the query returns YES*/

(Operation: decrease the output voltage to be below the OVP value or increase the

OVP value to be greater than the output voltage)
:OUTP:OVP:CLEAR CH1 /*Clear the label of the overvoltage protection occurred

on CH1*/

:OUTP:OVP:QUES? CH1 /*Query whether OVP occurred on CH1 and the query

returns NO*/