RIGOL DP832A User Manual
Page 115
RIGOL
DP800 Programming Guide
2-91
[:SOURce[
Syntax
[:SOURce[
{
[:SOURce[
Description
Set the step of the voltage change of the specified channel.
Query the step of the voltage change of the specified channel.
Parameter
Name
Type
Range
Default
[
Integer
1|2|3
1
Real
0 to the maximum voltage of
the specified channel
Refer to the
"Explanation"
Explanation
When [:SOURce[
corresponding parameter of the channel currently selected.
value. The default values of
Model
Default Value of
DP831A/DP832A/DP821A/DP811A
DP831
[1]
DP832/DP821/DP811
[1]
0.001V
CH1: 0.001V; CH2/CH3: 0.01V
0.01V
Note
[1]
: When DP831 (DP832, DP821 or DP811) is installed with the high resolution
option, its default step value is the same with that of DP831A (DP832A, DP821A or
DP811A).
When the parameter in the
[:SOURce[
to UP or DOWN, the voltage will increase or decrease at the step set by this
command when this command is executed.
Return Format
The query returns the step of the voltage change of the specified channel, for
example, 0.100V.
Example
:VOLT:STEP 0.1 /*Set the step of the voltage change of the current channel to
0.1V*/
:VOLT:STEP? /*Query the step of the voltage change of the current channel
and the query returns 0.100V*/
Related
Command
[:SOURce[